火焰原子吸收光谱法测定氟钛酸钾、氟硼酸钾、氟锆酸钾中钠含量
CSTR:
作者:
作者单位:

广东省科学院工业分析检测中心, 广东 广州 510650

作者简介:

王芳(1980—),女,安徽肥东人,硕士,高级工程师,主要从事化学分析检测工作。

通讯作者:

中图分类号:

O657.3;TF801+.3

基金项目:

高性能稀散金属复合材料省级质量标准实验室(1425159001)


Determination of sodium content in potassium fluotitanate, potassium fluoborate and potassium fluorozirconate by flame atomic absorption spectrometry
Author:
Affiliation:

Center for Industrial Analysis and Testing, Guangdong Academy of Science, Guangzhou 510650 ,China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    钠的含量是评价氟钛酸钾、氟硼酸钾、氟锆酸钾产品质量的重要指标,但目前无相关标准方法对氟钛酸钾、氟锆酸钾中钠的含量进行检测。针对此问题,本研究进行了多种酸对样品进行前处理的试验,并考察了钛基体和锆基体对钠测定的影响。结果表明,采用“硫酸溶解+硫酸冒烟赶氟”的方法对氟钛酸钾、氟硼酸钾、氟锆酸钾样品进行预处理,三个样品均可以溶解完全;在选定的条件下,钛和锆基体对钠元素测定无影响;测定过程无需加入消电离剂氯化铯和氯化锶;该方法的加标回收率在84.0%~113.9%之间,与电感耦合等离子体原子发射光谱法的测定结果一致;本法的相对标准偏差在5.39%~9.5%之间,能够满足快速准确测定氟钛酸钾、氟硼酸钾、氟锆酸钾中钠含量的需要,测定范围为0.0050%~0.5000%。本研究结果对于现有标准关于氟化盐中钠的测定具有重要的补充作用。

    Abstract:

    The content of sodium are important indexes to evaluate the quality of potassium fluotitanate, potassium fluoroborate and potassium fluorozirconate. At present, there are no relevant standard methods for the analysis of sodium in potassium fluotitanate and potassium fluorozirconate. The determination method of sodium in potassium fluoroborate can no longer meet determination of sodium in potassium fluotitanate and potassium fluorozirconate. In order to solve this problem, this study carried out experiments of pretreatment of samples with various acids, and investigated the effects of titanium matrix and zirconium matrix on sodium determination. The results show that potassium fuotitanate, potassium fluoborate and potassium fluorozirconate samples can be completely dissolved by the method of “sulfuric acid dissolution+sulfuric acid smoking” to drive away fluorine. Under the selected conditions, titanium and zirconium matrix have no effect on the determination of sodium; Deionizing agents cesium chloride and strontium chloride are not needed in the determination process. The recovery rate of this method is between 84.0% and 113.9%, which is consistent with the determination results of inductively coupled plasma emission spectrometry. The relative standard deviation of this method is between 5.39% and 9.56%, which can meet the needs of rapid and accurate determination of sodium content in potassium fluotitanate, potassium fluoborate and potassium fluoacetate, and the determination range is 0.0050%~0.5000%. The study is an important supplement to the existing standards for the determination of sodium in fluoride salt.

    参考文献
    相似文献
    引证文献
引用本文

王芳,周明俊,王津.火焰原子吸收光谱法测定氟钛酸钾、氟硼酸钾、氟锆酸钾中钠含量[J].中国有色冶金,2025,54(5):121-127.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-04-30
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-12-18
  • 出版日期:
文章二维码