Analysis of corrosion in desulfurization induced draft fans and technological retrofit
CSTR:
Author:
Affiliation:

Xingnan Environmental Protection Technology Co., Ltd., Hengfeng 334300 , China

Clc Number:

TQ116.02

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In response to the significant deviation between actual operating flue gas parameters and design parameters during the desulfurization production of a copper smelting project, which caused severe condensation and corrosion in the front-end fan and piping of the dynamic wave system, this study systematically analyzed various factors, including the desulfurization process, design data, operating parameters, and fan materials. Starting from the corrosion mechanism, and combining theoretical analysis, data evaluation, and practical investigation, the root causes of the problem were thoroughly explored, and a targeted technical modification plan was developed. The implementation of this plan effectively resolved the equipment condensation and corrosion issues, significantly improved the operational availability and production efficiency of the system, and reduced both the copper processing cost per ton and the SO2 removal expenses.

    Reference
    Related
    Cited by
Get Citation

孔波.脱硫引风机的腐蚀情况分析及技术改造[J].有色设备,2025,39(3):117-124.