Fault Analysis and Treatment of the Speed Regulating System of Dresser-Rand Extraction Turbine
CSTR:
Author:
Affiliation:

Clc Number:

TK263

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    This paper takes the Dresser-Rand extraction turbine as an example, in view of the failure phenomenon of speed out of control in the starting process of the unit, made a simulation test of the control equipment of speed regulating system by utilizing the valve calibration function of 505E digital controller, determines the cause of failure through comprehensive analysis, summarizes practical experiences in the fault treatment of speed out of control of exhaust turbine, and provides reference for the fault treatment of the speed control system of similar units.

    Reference
    Related
    Cited by
Get Citation

马红民.德莱赛兰抽汽式透平机调速系统的故障分析与处理[J].有色设备,2022,36(4):81-86.