Abstract:According to the relevant national standards and international standards of roads lighting, and combined with the actual working condition of factory road, this article studied and analyzed the selection of evaluation indicators of road lighting in industrial projects. The uniformity, longitudinal uniformity, surround ratio and dazzle should be determined according to the CIE standard. The standard values of the average brightness and average illuminance of the pavement can be determined according to the national standards. Then, combined with practical engineering experience, DIALUX software was used for simulation calculation, the selection of road lighting lamps, light sources and lamp layout in the actual design were proposed.